Dimensional and Engineering Data on Shaffer Type

Dimensional and Engineering Data on Shaffer Type LWP and LWS Hydraulic Blowout Preventers

 

 

DIMENSIONAL AND ENGINEERING DATA ON SHAFFER TYPE LWP HYDRAULIC BLOWOUT PREVENTERS

Refer to Dimensional Drawings – Fig. 49 and Fig. 50

SizeMax. Service Press. Rating PSIVertical BoreMax. Ram SizeApprox. Weight Lbs.HeightWidthLengthCenter ToDoor Open ToClosing RatioOpening RatioU.S. Gals. Fluid
Press.Test PSISingleDoubleSingle
Studded Flange
Single
Bolted Flange
Double
Studded Flange
Double
Bolted Flange
FrontRearChange RamsOpen RamsTo Close RamsTo Open Rams
6″3,0006,0007 1/16″5 9/16″906162514 7/16″19 1/8″21 7/830½”18 7/1652 3/8″8 5/16″10 1/8″22″33½”4 to 12.5 to 1.55.51
8″3,0006,0009″7″1245195010 11/16″20 11/16″23 7/833 3/4″22 1/1660 1/16″9¾”12 5/16″31 5/16″34 1/6″4 to 11.8 to 1.77.68

 

DIMENSIONAL AND ENGINEERING DATA ON SHAFFER TYPE LWS HYDRAULIC DOUBLE BLOWOUT PREVENTERS

SizeMax. Service Pressure Rating PSITest PSIVertical BoreApprox. Weight Lbs.Max. Ram SizeHeightWidthLengthCenter ToDoor Open ToClosing RatioOpening RatioU.S. Gals. Fluid
Studded FlangeBolted FlangeFrontRearChange RamsOpen RamsTo Close RamsTo Close Rams
6″3,0006,0007¼”24005 9/16″26 3/4″36 5/821 1/2589 5/1612 1/821344.44 to 11.2 to 11.01.85
6″5,00010,0007 1/16″28005 9/16″26 3/4″39 1/221 1/2589 5/1612 1/821344.44 to 11.2 to 11.01.85
6″3,0006,000939007″29 1/2″41 5/825 3/479 1/211  1/214 5/823465.56 to 11.89 to 12.752.3
6″5,00010,000939007″29 1/2″45 1/225 3/479 1/211 1/214 5/823465.56 to 11.89 to 12.752.3
10″3,0006,00011″44008 5/8″29 1/2″41 1/226 1/472 5/811 7/1614 11/1421424.44 to 11.78 to 11.561.3
10″5,00010,0001170008 5/833″50 1/228 3/489 1/412 3/41632465.5 to 11.5 to 13.252.7
12″3,0006,00013⅝630010 3/434 1/2″47 3/831 7/892 3/413 5/818 1/427535.56 to 11.89 to 13.552.9
13⅝”5,00010,00013⅝”970010 3/8″36″49 5/833 5/892 3/414 3/418 7/841545.5 to 11.5 to 13.552.9
16″3,0006,00016¾”85001335″5133106 1/216 1/220 1/832505.6 to 11.89 to 13.63.2